Composite Flexible Electrical Aramid Ama Insulation Paper Materials

Composite Flexible Electrical Aramid Ama Insulation Paper Materials

AMA Aramid paper composite insulating materials is a three-layer flexible composite material, produced by using F Class adhesive to adhere the polyester film.

Type
AMA Aramid Paper Composite Insulating Materials
Insulation Grade
F
Composition
Domestic Aramid Paper + polyester film + domestic Aramid Paper
Width
normal width 914mm
Thickness
0.15 mm-0.35mm
ISO 9001:2015 ISO 14001:2015 ISO 45001:2018 UL E310670 RoHS REACH

Description

AMA Aramid paper composite insulating materials is a three-layer flexible composite material, produced by using F Class adhesive to adhere the polyester film with Aramid paper on both sides.

Technical Specifications

ItemUnitRequirement
Nominal thicknessmm0.150.170.190.220.240.260.310.370.41
Thickness tolerancemm±0.022±0.024±0.026±0.031±0.037±0.041
Grammageg/m2150±18170±20200±24230±27270±32305±36360±43450±54515±61
Film nominal thicknessum365075100125150188250300
Tensile strengthMD no bendingN/10mm≥150≥150≥170≥190≥220≥240≥270≥330≥370
 MD after bending ≥90≥90≥105≥120≥150≥180≥200≥300≥330
 TD no bending ≥80≥90≥100≥110≥130≥170≥200≥250≥300
 TD after bending ≥70≥70≥90≥100≥120≥150≥150≥200≥230
ElongationMD%≥15≥3
(%)
TD ≥20≥10
Breakdown voltageNo bending ≥7≥8≥11≥12≥14≥16≥19≥23≥25
KV
After bending ≥6≥7≥9≥10≥12≥14≥15≥18≥19
Delamination—No Delamination, no bubble or other defects
Heat affected(200±2℃) 10min No Delamination, no bubble, no adhesive flow
Long-term heat resistance ≥180
(temperature index TI)
Weight and area conversionm2/Kg7.236.335.184.393.83.362.852.281.97

Advantages

AMA Aramid paper composite insulating materials has excellent heat-resistant, electrical, and mechanical properties. It is totally according with the standard of NMN (GB/T5591.3-2008), and it has the very similar property as NMN. It's perfect substitute of NMN.

Applications

AMA Aramid paper composite insulating materials is suitable for slot-to-slot insulation, phase-to-phase and turn-to-turn insulation of F-class motors, and can be used as interlayer insulation for transformers and other electrical appliance.

Storage & Notice

1. During slitting and use, edge gaps and cracks should be prevented to avoid tearing during operation and to avoid surface scratches, oil and dust pollution.

2. Store in an environment below 40℃, keep clean and dry, away from heat sources, and avoid direct sunlight.

3. The storage period is one year. If it exceeds the storage period, it can still be used if it passes the test according to the technical requirements.

Specifications

ItemUnitRequirement
Nominal thicknessmm0.150.170.190.220.240.260.310.370.41
Thickness tolerancemm±0.022±0.024±0.026±0.031±0.037±0.041
Grammageg/m2150±18170±20200±24230±27270±32305±36360±43450±54515±61
Film nominal thicknessum365075100125150188250300
Tensile strengthMD no bendingN/10mm≥150≥150≥170≥190≥220≥240≥270≥330≥370
 MD after bending ≥90≥90≥105≥120≥150≥180≥200≥300≥330
 TD no bending ≥80≥90≥100≥110≥130≥170≥200≥250≥300
 TD after bending ≥70≥70≥90≥100≥120≥150≥150≥200≥230
ElongationMD%≥15≥3
(%)
TD ≥20≥10
Breakdown voltageNo bending ≥7≥8≥11≥12≥14≥16≥19≥23≥25
KV
After bending ≥6≥7≥9≥10≥12≥14≥15≥18≥19
Delamination—No Delamination, no bubble or other defects
Heat affected(200±2℃) 10min No Delamination, no bubble, no adhesive flow
Long-term heat resistance ≥180
(temperature index TI)
Weight and area conversionm2/Kg7.236.335.184.393.83.362.852.281.97