Diamond Paper Insulation Paper For Isolation Transformers

Diamond Paper Insulation Paper For Isolation Transformers

The thermal class covers: B, F, H, N,and C , the enterprise is managed strictly according to ISO9001 system (Registered No.: E03817Q01957R2M), and passed UL.

ISO 9001:2015 ISO 14001:2015 ISO 45001:2018 UL E310670 RoHS REACH

Description

The thermal class covers: B, F, H, N,and C , the enterprise is managed strictly according to ISO9001 system (Registered No.: E03817Q01957R2M), and passed UL approval ( File No. : E345432) ,all products comply with IEC standard and ROHS as well as REACH test.   Description: Made of electrical insulation paper with diamond shape epoxy resin dotted in both sides.   Features and application: Good dialectric and mechnical properties after being heat-solidafication. As interturn insulation for coils of oil-immersed transformers and interlayer insulation of distribution transformers.   Availability: 0.08mm, 0.13mm, 0.18mm, 0.20mm, 0.25mm. MD: Machine Direction. CD: Cross-machine Direction

Technical Specifications

C1

Thickness

mm

0.08

0.13

0.17

0.20

0.25

0.30

0.40

2

Thickness Tolerance

%

6.5

3

Density

g/cm3

≥0.85

4

Tensile Strength

MD

KN/m

7.5

CD

3.7

5

Tear Strength

m·N

500

1000

1500

2000

6

Dielectric Breakdown

Kv

0.6

0.9

1.2

2.2

2.75

3.3

4.4

7

Aqueous Extract

—

6.8~8.5

8

Bond Strength

Kpa

450

9

Ash Content

%

1.0

10

Moisture Content

%

8±1

11

Cure Temperature And Time

—

Low temp. 90±5℃≥3h, then high temp. 120±5℃≥6h

12

Storage Condition

—

storage temp.: ≤35℃

Stored in dry, clean and ventilated condition.

Away from the fire, high temperature and direct sunshine.

Specifications

C1

Thickness

mm

0.08

0.13

0.17

0.20

0.25

0.30

0.40

2

Thickness Tolerance

%

6.5

3

Density

g/cm3

≥0.85

4

Tensile Strength

MD

KN/m

7.5

CD

3.7

5

Tear Strength

m·N

500

1000

1500

2000

6

Dielectric Breakdown

Kv

0.6

0.9

1.2

2.2

2.75

3.3

4.4

7

Aqueous Extract

—

6.8~8.5

8

Bond Strength

Kpa

450

9

Ash Content

%

1.0

10

Moisture Content

%

8±1

11

Cure Temperature And Time

—

Low temp. 90±5℃≥3h, then high temp. 120±5℃≥6h

12

Storage Condition

—

storage temp.: ≤35℃

Stored in dry, clean and ventilated condition.

Away from the fire, high temperature and direct sunshine.

INQUIRY CHANNEL

Have an upcoming project? Let's talk.

Send us your required specifications (thickness, width, quantity) and we will send a customized quotation within 12 hours.

✉
☏

WhatsApp / Phone

+86 19937408623