Composite insulation papers combine multiple materials to achieve properties that no single material can deliver alone. The three most common types — DMD, NMN, and NHN — each serve specific thermal and mechanical requirements.

DMD (Class F 155°C)

Structure: Polyester non-woven + Polyester film + Polyester non-woven (3 layers)

Best for: General-purpose Class F motors, cost-sensitive applications

Strength: Excellent mechanical toughness, good slot filling, economical

Breakdown voltage: 8-15 kV/mm

NMN (Class H 180°C)

Structure: Nomex aramid paper + Polyester film + Nomex aramid paper

Best for: Traction motors, wind generators, dry-type transformers

Strength: Superior thermal aging, chemical resistance, edge-tear resistance

Breakdown voltage: 12-20 kV/mm

NHN (Class H/C 180-220°C)

Structure: Nomex aramid paper + Polyimide film + Nomex aramid paper

Best for: High-voltage motors, EV traction, extreme temperature applications

Strength: Highest thermal margin, corona resistance, space-saving

Breakdown voltage: 20-40 kV/mm

Quick Selection Guide

• Budget motor → DMD (Class F, best value)
• Industrial/traction motor → NMN (Class H, proven reliability)
• High-voltage/extreme duty → NHN (Class C, maximum margin)